426 Ultra Enterprise 450 Server Owner’s Guide July 1997
Environmental Requirements
The operating and non-operating environmental requirements for the system are
as follows.
Agency Compliance Specifications
The system complies with the following specifications.
Parameter Value
Operating
Temperature 5˚C to 35˚C (41˚F to 95˚F)—IEC 68-2-1, 68-2-2
Humidity 20% to 80% RH, noncondensing; 27 ˚C max wet bulb—IEC 68-2-2,
68-2-3
Altitude 0 to 3000 meters (0 to 10,000 feet)—IEC 68-2-40, 68-2-41
Vibration 0.2 gravity (g) peak, 5–500 Hz, 3 perpendicular axes—IEC 68-2-6
Shock 4g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
Acoustic Noise 49/55 dB(A) closed office (idle/seeking)
57/65 dB(A) open area (idle/seeking)
Non-Operating
Temperature -20˚C to 60˚C (-4˚F to 140˚F)—IEC 68-2-1, 68-2-2
Humidity 95% RH, noncondensing at 40˚C—IEC 68-2-2, 68-2-3
Altitude 0 to 12,000 meters (0 to 40,000 feet)—IEC 68-2-40, 68-2-41
Vibration 1g peak, 5–500 Hz, 3 perpendicular axes—IEC 68-2-6
Shock 30g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
Handling Drops 50 mm—IEC 68-2-31
Threshold Times-
Roman
1 m/s—SUN 900-1813
Category Relevant Standards
Safety EN60950/IEC950 DEMKO, TUV
UL 1950, CB Scheme IEC 950, C22.2 No. 950 from UL
RFI/EMI EN55022/CISPR22 Class B
VCCI Class II
FCC part 15 Sub Part B
Immunity EN50082/IEC-1000-2
IEC-1000-3
IEC-1000-4
IEC-1000-5
X-ray DHHS 21 Subchapter J
PTB German X-ray Decree