10-2 Status Display
Power-Up Error Codes
A power-up error indicates in almost all cases that the drive should be
returned to the factory for service. In general, any occurrence of a
Power-up error should be treated with extreme caution. It may
indicate the hardware is marginal.
Situations that may cause drive hardware errors, and which can be
remedied outside the factory include:
A watchdog time-out error may result from electrical “noise”
(electromagnetic interference - EMI), a firmware error, or a hardware
malfunction. The context of the watchdog error needs to be
investigated to determine the source of the problem.
Table 10.2 lists the Power-Up Error Codes.
21 Auxiliary Encoder State Error
22 Motor Thermal Protection
23 IPM Thermal Protection
24 Excess Velocity Error
25 Commutation Angle Error
26 Reserved
27 Axis not Homed
28 No Motor Selected
29 Motor Selection not in Table
30 EEPROM Write Error
31 - 50 Reserved
Table 10.1: List of Run Time Error Codes (continued)
Error Code Fault Description
Table 10.2: List of Power-Up Error Codes
Error Code Fault Description
51 Program Memory Boot Block Error
52 Program Memory Main Block Error
53 Uninitialized Personality EEPROM Error
54 Personality EEPROM Read Error
55 Personality EEPROM Data Corruption
56 Processor Watchdog Error
57 Reserved
58 Processor RAM Error
59 Reserved
60 Uninitialized Service EEPROM Error
61 Service EEPROM Read Error
62 Service EEPROM Data Corruption Error
63 - 73 Reserved
74 Personality EEPROM Write Error
75 - 78 Reserved